ACME E-FIELD Flames
PSI-22Needs reviewAdvanced Combustion via Microgravity Experiments Electric-Field Effects on Laminar Diffusion Flames
Needs review: this record is flagged for a manual check. Confirm values against the linked sources before relying on them.
Objectives
- The objective of this investigation is to better understand the relationship between electric field voltage and chemi-ion current, analyze the dynamic response of flames to electric field changes, evaluate soot formation, and characterize stabilized near-limit lifted flames.
The E-FIELD flames experiment investigates how electric fields influence the behavior of laminar diffusion flames in microgravity. This unique environment is ideal for isolating electric field effects from buoyancy forces. The experiment is conducted with gas-fueled flames, both with and without a coflow of air. In the former case, the tests are conducted using the same coflow burner used by the Coflow Laminar Diffusion (CLD) Flame experiment. An electric field is generated by creating a high voltage (up to 10 kV) differential between the burner and a flat circular mesh suspended above (i.e., downstream of) the burner. Measurements, as a function of the field strength and fuel, are taken of the ion current through the flame and the flame’s response time to electric forcing. The gas-jet burner is used to create a small, focused flame for detailed ion-driven convection studies while the coflow burner surrounds the fuel jet with a weak synthetic air flow to enable flame stability and soot behavior analysis. A high-voltage copper mesh electrode positioned above the burner tip generated an electric field with controlled polarity and strength. The electric field interacts with ions generated through chemi-ionization during combustion, driving ion-driving convection and influencing flame behavior. Methane and ethylene were used as fuels and diluted with nitrogen to control flame strength. Dilution levels were varied to explore a range of combustion dynamics, from highly stable to near-extinction flames. Voltage-current curves were recorded to assess the relationship between electric field strength and chemi-ion current, revealing ion-driven convection effects. High-resolution cameras captured flame shape, luminosity, and soot distribution. Spectral imaging with filters measures chemiluminescent emissions and soot volume fraction. There were thermopile detectors to measure flame radiant emissions. All experiments were conducted in the combustion integrated rack (CIR). Tests were administered with Glenn Research Center (GRC) directing astronaut actions. Parameters such as fuel flow rate, coflow velocity, and field polarity are were varied to isolate specific effects on ion production, flame stability, and soot behavior.
Conditions
| Parameter | Tested value or range | Unit |
|---|---|---|
| Oxygen | – | % by volume |
| Pressure | – | psi |
| Pressure | – | kPa |
| Airflow | – | cm/s |
| Gravity | Microgravity | |
| Diluents | nitrogen | |
| Fuel phase | Gas | |
| Fuels | 100% CH4, 40% CH4, 100% C2H4, 30% C2H4 | |
| Sample geometry | – | |
| Sample size | – | as stated |
| Hardware | CIR | |
| Platform | ISS | |
| Years | 2016-2020 |
A dash means the sources do not state the value.
Variables varied
None recorded.
Variables held fixed
None recorded.
Sensors
None recorded.
Findings (1)
Key findings
The experimental table lists coflow-burner days, fuel bottles, and mesh polarity. It does not state an oxygen percentage or a pressure.
Tests (21)
| Test | Sample | Fuel | Sample geometry | O2 (%) | Pressure (psi) | Airflow (cm/s) | Diluent | Outcome | Spread rate (mm/s) | Notes |
|---|---|---|---|---|---|---|---|---|---|---|
| PSI-22-T1 | 18073 | 100% CH4 | – | – | – | – | – | Not stated | – | First round of tests with coflow burner; mesh polarity negative; fuel concentration 100%; flames ignited 10; Test day is formatted YYDDD where YY identifies year and DDD identifies day of year (GMT). |
| PSI-22-T2 | 18078 | 100% CH4 | – | – | – | – | – | Not stated | – | First round of tests with coflow burner; mesh polarity negative; fuel concentration 70%; flames ignited 10; Mesh polarity refers to the polarity of the high-voltage power supply and the copper electrode relative to the burner. |
| PSI-22-T3 | 18080 | 40% CH4 | – | – | – | – | – | Not stated | – | First round of tests with coflow burner; mesh polarity negative; fuel concentration 40%; flames ignited 8; Flames Ignited is the number ignited on that day (neglecting the day change on ISS). |
| PSI-22-T4 | 18087 | 100% C2H4 | – | – | – | – | – | Not stated | – | First round of tests with coflow burner; mesh polarity negative; fuel concentration 80%; flames ignited 10 |
| PSI-22-T5 | 18092 | 30% C2H4 | – | – | – | – | – | Not stated | – | First round of tests with coflow burner; mesh polarity negative; fuel concentration 30%; flames ignited 11 |
| PSI-22-T6 | 18095 | 30% C2H4 | – | – | – | – | – | Not stated | – | First round of tests with coflow burner; mesh polarity positive; fuel concentration 30%; flames ignited 10 |
| PSI-22-T7 | 18102 | 40% CH4 | – | – | – | – | – | Not stated | – | First round of tests with coflow burner; mesh polarity positive; fuel concentration 40%; flames ignited 8 |
| PSI-22-T8 | 18106 | 40% CH4 | – | – | – | – | – | Not stated | – | First round of tests with coflow burner; mesh polarity positive; fuel concentration 40%; flames ignited 13 |
| PSI-22-T9 | 18113 | 100% CH4 | – | – | – | – | – | Not stated | – | First round of tests with coflow burner; mesh polarity positive; fuel concentration 100%; flames ignited 15 |
| PSI-22-T10 | 18130 | 100% CH4 | – | – | – | – | – | Not stated | – | First round of tests with coflow burner; mesh polarity positive; fuel concentration 70%; flames ignited 13 |
| PSI-22-T11 | 18137 | 100% C2H4 | – | – | – | – | – | Not stated | – | First round of tests with coflow burner; mesh polarity positive; fuel concentration 80%; flames ignited 12 |
| PSI-22-T12 | 18269 | 40% CH4 | – | – | – | – | – | Not stated | – | Second round of tests with gas-jet burner; mesh polarity negative; fuel concentration 40%; flames ignited 11 |
| PSI-22-T13 | 18274 | 30% C2H4 | – | – | – | – | – | Not stated | – | Second round of tests with gas-jet burner; mesh polarity negative; fuel concentration 30%; flames ignited 11 |
| PSI-22-T14 | 18282 | 100% CH4 | – | – | – | – | – | Not stated | – | Second round of tests with gas-jet burner; mesh polarity negative; fuel concentration 70%; flames ignited 13 |
| PSI-22-T15 | 18285 | 100% C2H4 | – | – | – | – | – | Not stated | – | Second round of tests with gas-jet burner; mesh polarity negative; fuel concentration 100%; flames ignited 10 |
| PSI-22-T16 | 18290 | 100% C2H4 | – | – | – | – | – | Not stated | – | Second round of tests with gas-jet burner; mesh polarity negative; fuel concentration 80%; flames ignited 11 |
| PSI-22-T17 | 18298 | 40% CH4 | – | – | – | – | – | Not stated | – | Second round of tests with gas-jet burner; mesh polarity positive; fuel concentration 40%; flames ignited 9 |
| PSI-22-T18 | 18302 | 30% C2H4 | – | – | – | – | – | Not stated | – | Second round of tests with gas-jet burner; mesh polarity positive; fuel concentration 30%; flames ignited 10 |
| PSI-22-T19 | 18312 | 100% CH4 | – | – | – | – | – | Not stated | – | Second round of tests with gas-jet burner; mesh polarity positive; fuel concentration 70%; flames ignited 13 |
| PSI-22-T20 | 18319 | 100% C2H4 | – | – | – | – | – | Not stated | – | Second round of tests with gas-jet burner; mesh polarity positive; fuel concentration 25%; flames ignited 11 |
| PSI-22-T21 | 18319 | 100% C2H4 | – | – | – | – | – | Not stated | – | Second round of tests with gas-jet burner; mesh polarity positive; fuel concentration 25%; flames ignited 11 |