SAFFIRE-I
PSI-98PreventionSpacecraft Fire Safety Experiment-I
Objectives
- determine how rapidly a large scale fire grows in low-gravity
- investigate the low-g flammability limits compared to those obtained in NASA’s normal gravity material flammability screening test.
The Saffire-1 experiments was performed on the Orbital Science’s Cygnus resupply vehicle after it deberthed from the ISS. The sample material for Saffire-I is a composite fabric called Sibal consisting of cotton on a fiberglass substrate (75% cotton, 25% fiberglass by weight). It has been used in many space experiments because it burns like cotton but maintains structural integrity after the cotton is consumed. The sample was approximately 0.94 meters long and 0.4 meters wide, simulating a large piece of flammable fabric. The Saffire-1 flight unit had a sample card installed in the middle of a large flow duct. Air is drawn through the flow duct by fans located at the top of the duct with flow straighteners at the bottom of the experiment module. Saffire-I was conducted at an air flow velocity of 20 cm/s. Once the sample was ignited flame images were captured using two cameras. In addition, thermocouples provided flow, flame, and plume temperatures, two radiometers recorded flame radiation, solid state sensors were used to measure pressure, CO2 and O2 mole faction, and two anemometer tracked flow velocity. All data was compressed, and subsequently downlinked.
Conditions
| Parameter | Tested value or range | Unit |
|---|---|---|
| Oxygen | 21.5 to 21.7 | % by volume |
| Pressure | – | psi |
| Pressure | – | kPa |
| Airflow | 20 | cm/s |
| Gravity | Microgravity | |
| Diluents | – | |
| Fuel phase | Solid | |
| Fuels | SIBAL cloth, cotton, fiberglass | |
| Sample geometry | planar | |
| Sample size | 94 cm x 40.6 cm | as stated |
| Hardware | Other | |
| Platform | ISS | |
| Years | 2001-2008 |
A dash means the sources do not state the value.
Variables varied
- burn time
Variables held fixed
- sample thickness
- sample length
- sample width
- air flow
- ignition power
- ignition time
Sensors
- thermocouples
- radiometers
- solid-state CO2 sensor
- solid-state O2 sensor
- solid-state pressure sensor
- anemometers
- cameras
- smoke wire
Findings (2)
Flame spread
S1 was a concurrent SIBAL burn that lasted 420 s. The table states its oxygen as 21.5 - 21.7 percent.
S2 was an opposed SIBAL burn that lasted 70 s. The table states its oxygen as approximately 21.5 percent.
Fire safety relevance
The Saffire-I experiment provides a new way to study a realistic fire on an exploration vehicle, which has not been possible in the past because the risks are too high. Instruments on an unmanned cargo vessel measure oxygen, carbon dioxide, heat, pressure and flame growth, and two video cameras provide views of the flame. Results determine microgravity flammability limits for several spacecraft materials, help to validate NASA’s material selection criteria, and how microgravity and limited oxygen affect flame size. The investigation is crucial for the safety of current and future space missions.
Oxygen and airflow
Tests that state both oxygen and airflow. Ignited and extinguished marks are the outcomes the source records, so the change from one mark to the other is the limit those tests show.
- Not stated
Tests (4)
| Test | Sample | Fuel | Sample geometry | O2 (%) | Pressure (psi) | Airflow (cm/s) | Diluent | Outcome | Spread rate (mm/s) | Notes |
|---|---|---|---|---|---|---|---|---|---|---|
| PSI-98-T1 | S1 | SIBAL Fabric | Thickness: 0.37 cm, Length: 40.6 cm, Width: 94 cm | – | – | 20 | – | Not stated | – | Ignition Power: 182 W, Ignition Time: 8 s, Burn Time: 420 s, Flow Direction: Concurrent, Camera 1: S1C1, Camera 2: S1C2; Oxygen is stated as 21.5 - 21.7, not a single measured point. |
| PSI-98-T2 | S2 | SIBAL Fabric | Thickness: 0.37 cm, Length: 40.6 cm, Width: 94 cm | 21.5 | – | 20 | – | Not stated | – | Ignition Power: 182 W, Ignition Time: 8 s, Burn Time: 70 s, Flow Direction: Opposed, Camera 1: S2C1, Camera 2: S2C2; Oxygen is stated as approximately 21.5. |
| PSI-98-T3 | F1C1/F1C2 | – | – | – | – | – | – | Not stated | – | Material: Pre-test flow visulation data for sample 1 |
| PSI-98-T4 | F2C1/F2C2 | – | – | – | – | – | – | Not stated | – | Material: Pre-test flow visulation data for sample 2 |